Measuring range and temperature range: dependent on the sensor.
For operation rod sensor, external resp. customer specific sensor and calibration required.
Power supply 24VDC (15 to 29VDC), automatic temperature compensation, large, well-lit LC display, analogue output 4-20mA for water content.
Further sensors on request (dependent on the application).
art. no. | picture | Extended accessories: |
---|---|---|
12327 | Option for temperature measurement Sample temperature measurement 5 to + 85°C, temperature scaling (4-20mA) 0.2mA / °C |
|
11217 | Laboratory analysis for preparation of a calibration curve for a new material for humimeter devices | |
12297 | Entry of an existing characteristic curve in a humimeter device | |
13585 | Electrode 40mm length, made of stainless steel, Ø3,8mm, without insulation | |
13605 | Cable for sawn timber drying chamber of 5 meters length, for connection of 2 electrodes article no. 13585 to universal material moisture transmitter article no. 12849 | |
13606 | Cable with temperature sensor (5 meters length) for sawn timber drying chamber, for connection to universal material moisture transmitter article no. 12849 |