humimeter RH2
Precise handheld thermo-hygrometer with Datalogger

Precise thermo- hygrometer with exchangeable external sensors for a wide range of applications with manual- & autodatalogfunction for laboratory, synthetic granules, climate and environment applications.

 

By selecting different long term stable sensors, the range of applications goes from the measurement of air humidity to the determination of relative material moisture via material moisture sensor to the determination of water activity value in diverse food.

 

The RH2 could also be connected with a infrared (IR) temperature sensor for temperature measurement from a distance without contact with the object or with a CO2 (carbon dioxide) sensor to measure the quality of air for example in classrooms, meeting rooms, laboratories or greenhouses.

 

The humimeter RH2 handheld thermo- hygrometer measures relative humidity, absolute humidity, dew point, equilibrium moisture content, aw-value, CO2 concentration (ppm) and temperature.

 

Features

 

Your benefits

  • Relative humidity, absolute humidity, dew point, equilibrium moisture content, aw-value
  • Selectable sensor types
  • Long stable humidity- and temperature sensors
  • Easy data storage at the portable moisture meter
  • Analysis on the PC and printer available
  • Optimal documentation of your quality
  Termohigrometr ręczny z sondą na przewodzie

 

Extended accessories

Art. No. Picture Extended accessories
12032 Moisture and Temperature Sensor with 2 meter connection cable. Powered by RH2, relative humidity 0 to 100%, calibration 0 to 90% +/- 2,5% (at 25°C), Temperatur range -20 to + 85 °C, calibration +/93/czujnik-wilgotnosci-i-temperatury-12032.jpg Moisture and Temperature Sensor with 2 meter connection cable.
Powered by RH2, relative humidity 0 to 100%,
calibration 0 to 90% +/- 2,5% (at 25°C), Temperatur range -20 to + 85 °C,
calibration +/- 0,5 °C (at 25 °C), rapid conditioning
12514   Air humidity and temperature sensor for humimeter GF2 and RH2
12004 Moisture and Temperature Sensor with 2 meter connection cable. Powered by RH2, relative humidity 0 to 100%, calibration 0 to 90% +/- 2,5% (at 25°C), Temperatur range -20 to + 85 °C, calibration +/94/czujnik-wilgotnosci-i-temperatury-do-pomiaru-wilgotnosci-materialu-12004.jpg LF_TB 120 Precision moisture and temperature plug-in sensor for material moisture, sensor head 0.3 m stainless tube with steel sinter cap and 2 meter connection cable.
Relative humidity 0 to 100%, calibration 10 to 90% r.h. +/- 1.5% r.h. (at 23°C), temperature range -20 to +100°C, calibration +/- 0.3°C (at 23°C), rapid conditioning
13700 Zestaw do pomiaru aktywności wody z czujnikiem wilgotności i temperatury 13700 Activity of water value measuring chamber and moisture and temperature sensor with connection cable of 2 meters length incl. 4 twist-off caps, 2 screw glasses 186ml and 2 screw glasses 245ml,
certified calibration ampoules - set of 5 (Art.No.: 10005), plastic case (Art.No.: 13624) and factory calibration certificate (Art.No.: 10403).
12964   CO2 sensor for humimeter (can only be ordered together with new device)
12513   Non-contact infrared temperature sensor for humimeter
13740   Jar replacement set with twist-off lid
for activity of water measuring chamber article no. 13700:
14 units for a filling quantity of max. 245 ml
13741   Jar replacement set with twist-off lid
for activity of water measuring chamber article no. 13700:
14 units for a filling quantity of max. 186 ml
12278 Oprogramowanie LogMemorizer humimeter USB data interface module with LogMemorizer measuring data
recording and analysing software on CD incl. USB cable for PC
12485 Oprogramowanie LogMemorizer z akumulatorami humimeter USB humimeter USB data interface module VERSION FOR RECHARGEABLE
BATTERIES with LogMemorizer measuring data recording and analysing
software on CD incl. USB cable
13340   Internal Bluetooth class 1, integrated module class 1 (up to 100 metres) for humimeter devices. Combinable with USB interface.
12627 Moduł bluetooth do rejestratorów Bluetooth data communication module for all humimeter devices with serial interface RS232 
10613   Paper web adapter for humimeter RH2 and LF_serie
13624   Plastic case for humimeter RH2
11988   Wall holder assembled on humimeter RH1/RH2
10249   Stainless steel sinter sensor cap, stainless steel sinter filter: for applications at high temperatures and harsh operating conditions
11733 Drukarka termiczna do rejestratorów Thermo printer runs by battery, industrial model, portable
10006 Zestaw do kalibracji czujnika Calibration equipment for instruments for probe
10005 Certyfikowane ampułki kalibracyjne - zestaw 5 sztuk Certified calibration ampules - set of 5.
2 x 35% r.h., 1 x 50% r.h., 2 x 80% r.h.
10352 Certyfikowane ampułki kalibracyjne - zestaw 5 sztuk Certified calibration ampules - set of 5, 50% r.h.
12166   Analogue output module for humimeter devices
13224   Extension cable of 8 meters for humimeter RH2 sensors

 

Description

In diverse industrial sectors, the careful and accurate monitoring of the room climate is an important process, significantly contributing to maintaining product standards and product quality. This process can be effected easily with the help of the humimeter RH2 hand held thermo hygrometer and climate meter.

 

The humimeter RH2 data logger for temperature and air humidity determines the absolute and relative air humidity as well as the dew point automatically. In addition, further information like surrounding temperature and sensor temperature are displayed.

Handling and measuring procedure

Control the room climate by placing the humimeter RH2 resp. the measuring sensor in a room. After a short conditioning time read off the desired measuring values. Via the integrated data logger for temperature and air humidity, a long-term monitoring of the room climate is possible.

 

Operation in practice

The humimeter RH2 hand held thermo hygrometer and climate meter can be used for monitoring the room climate in laboratories as well as in production and storage facilities. Effect random checks of temperature and room climate or use the integrated data logger for temperature and air humidity for effecting representative long-time measurements. The optionally available external sensors open up a wide range of application possibilities in the field of determining air humidity and dew point.

Call us