The humimeter SLW is a textile moisture meter with exchangeable electrodes. It measures the water content of natural and synthetic fabrics, yarn, fibres, knitted goods and finished articles - in production, at goods intake and in quality control.
A measurement takes a few seconds and needs no sample preparation. The materials the device is calibrated for include cotton, wool, linen, hemp, jute, viscose, acetate, acrylic, nylon and polyester.
The meter does not measure on its own. Two things are needed and both are bought separately: the electrode handle (art. no. 14800) with its BNC cable, and at least one electrode matched to the material. The handle is common to every electrode type, so extending the set later means buying electrodes only.
The choice of electrode follows the form of the material: needle electrodes for yarn, hanks and bobbins, the long rod electrode for sacks and bales, and the surface electrode wherever the fabric must not be pierced.
Main features
|
![]() |
| Parameter | Value |
|---|---|
| Measuring range | 0.3 to 30 % water content (depending on the material) |
| Resolution | 0.1 % water content |
| Temperature compensation | automatic |
| Material temperature when determining moisture | 0 to +40 °C |
| Temperature measuring range | -10 to +60 °C |
| Measuring time | a few seconds, with no sample preparation |
| Memory | hold function, manual data logger for 10 000 readings with measuring point reports |
| Dimensions of the base unit | 335 × 74 × 62 mm |
| Weight of the base unit | 450 g (with batteries) |
| Power supply | 4 × 1.5 V AA alkaline batteries |
| Menu languages | English, German, French, Italian, Spanish, Portuguese, Czech, Russian, Polish and an international version |
| Article number | 12942 (base unit, without electrodes) |
The electrodes are not part of the delivery - the handle 14800 and the chosen electrode are ordered separately.
| Art. no. | Picture | Description |
|---|---|---|
| 14800 |
![]() |
SLW-HE - handle for the hand electrodes, fitting every electrode type in this list, with a 1 m BNC cable for connection to the humimeter SLW (art. no. 12942) |
| 13727 |
![]() |
SLW-E025 - eight-needle electrode, needle length 25 mm (cone diameter 0.5-1.75 mm). Use: hanks, yarn, yarn on bobbins, cross-wound bobbins, fabrics, fabric rolls, knitted goods |
| 14989 |
![]() |
SLW-E025-S - two-needle electrode, needle length 25 mm (cone diameter 0.5-1.75 mm). Use: as above, for smaller and more delicate samples |
| 13728 |
![]() |
SLW-E100 - needle electrode, needle length 100 mm (cone diameter 0.7-3 mm). Use: hanks, cones, bobbins, knitted goods, fabric rolls, yarns |
| 13729 |
![]() |
SLW-E325 - rod electrode, rod length 325 mm (cone diameter 2.5-6 mm). Use: measuring products in sacks and bales |
| 13730 |
![]() |
SLW-E023 - surface electrode, 23 mm in diameter, for measurements without piercing the material. Use: acetate, acrylic, hemp, jute, cotton, nylon, polyester, viscose, linen, wool |
The SLW measures with electrodes and reports the water content of the fibre itself. The humimeter RH5 tex measures with a sword probe pushed between the layers and reports the relative humidity of the air inside the stack, which the material has come into equilibrium with. Where a figure for a named fibre is needed, the SLW is the instrument; where a whole stack or bale is to be judged without being opened, the RH5 tex is.