humimeter FS4.2
Universal material moisture meter with customer-calibration function

Moisture measurement of salt, granulates and sewage sludge

The humimeter FS4.2 measures the water content of a weighed sample of bulk material. The sample does not have to be ground or prepared in any other way - a portion is weighed on the scale supplied with the device and poured into the measuring chamber. The result appears on the display within a few seconds, with automatic compensation of the material temperature.

The meter carries factory curves for road salt, table salt and sea salt as well as for sewage sludge granulate. For any other bulk material the curve is developed by the manufacturer’s laboratory. The FS4.2 replaced the discontinued FS4.1 model and took over its sewage sludge measurement.

What can be measured

Calibration curves and sample weight

The accuracy of the FS4.2 rests on weighing out a portion of the correct mass, which is why the digital scale and the measuring cup are part of the set. The name of the curve states the required sample weight, and the permitted deviation is ±1.0 g.

Calibration curveMeasuring rangeSample weight
Road salt, fine (below 1.5 mm)0-1.00 % water content400 g
Road salt, coarse (above 1.5 mm)0-1.00 % water content400 g
Table salt0-1.00 % water content400 g
Sea salt1.00-3.00 % water content400 g
Sewage sludge granulate10-55 % water content (45-90 % dry matter)260 g
Customer materialcurve developed in the manufacturer’s laboratory (art. no. 11217)depends on the material

How a measurement is taken

  1. Select the curve that matches the material - its name states the required sample weight.
  2. Place the empty measuring cup on the scale, zero the reading, then weigh out the sample to within ±1.0 g.
  3. Pour the material into the measuring chamber slowly and evenly.
  4. Read the water content from the display.

Keeping to the sample weight is the condition for a repeatable result: the meter converts the value measured in the chamber for a quantity of material known in advance, so a larger or smaller portion shifts the reading. This is how the bulk density is compensated - the FS4.2 does not determine or display a hectolitre weight.

Your own material - a curve to order

For granulates, powders and other bulk materials outside the list of factory curves, the manufacturer carries out a laboratory analysis of a sample and loads the finished curve into the meter (art. no. 11217). From that point the device measures that material exactly as it measures the salts, that is after a portion of the specified weight has been weighed out.

Checking the readings every four weeks

The operating manual recommends checking the calibration every four weeks. The check set art. no. 11758 serves that purpose, consisting of a check device and a weight - the same one needed for the supervision of measuring equipment according to the ISO standard.

Logging and transferring the data

The meter stores 10 000 readings in its manual logger and produces a measuring point report, so the place of measurement, the supplier and the batch number can be added to the result. The USB interface module with the LogMemorizer basic software is included in the scope of delivery, so transferring the data to a computer costs nothing extra. Instead of the cable an internal Bluetooth 5.0 module can be chosen (art. no. 14944), and the results can be printed on the spot with a portable thermal printer (art. no. 15444).

Advantages

  • a measurement in a few seconds, without grinding, drying or any other sample preparation
  • automatic compensation of the material temperature
  • bulk density compensated by weighing the portion on the scale supplied
  • five factory curves: four kinds of salt and sewage sludge granulate
  • a curve for any other bulk material developed in the manufacturer’s laboratory
  • logger for 10 000 readings with a measuring point report
  • USB interface module with LogMemorizer basic software included in the delivery
  • ten-year repair warranty and lifetime technical support from the manufacturer
humimeter FS4.2 moisture meter for salt, granulates and sewage sludge with the digital scale and the measuring cup

Technical data

Article number12069
Measuring range - salts0 to 1.00 % water content (road and table salt), 1.00 to 3.00 % (sea salt)
Measuring range - sewage sludge granulate10 to 55 % water content, that is 45 to 90 % dry matter
Measuring range - other granulates and powdersaccording to a curve developed individually for the material (art. no. 11217)
Resolution0.01 % water content for salts, 0.1 % for granulates; temperature 0.5 °C/°F
Compensationautomatic temperature compensation, bulk density compensated by weighing the sample
Resultwithin a few seconds, without sample preparation
Memory functionHold function, manual logger for 10 000 readings with a measuring point report
Operating temperature0 to +40 °C
Storage temperature-20 to +60 °C
Protection classIP 40
Displaybacklit dot matrix 128 × 64
Dimensions255 × 75 × 255 mm
Weight1300 g (with batteries)
Power supply4 × AA 1.5 V alkaline batteries
Menu languagesEnglish, German, French, Italian, Spanish, Portuguese, Czech, Polish, Russian, international

Scope of delivery

Neither the scale nor the measuring cup has to be bought separately - without them the measurement would not be repeatable, so the manufacturer supplies them with the set. The USB interface module is included as well and is not an extra charge.

Extended accessories

FS4.2 or SG1

Both meters cover bulk materials and powders, but they work differently. The FS4.2 measures a weighed sample in the measuring chamber, so the material has to be taken and brought to the device. The humimeter SG1 measures directly in the heap, the big bag or the chute with an insertion probe, without taking a sample, and needs probe art. no. 14924 to work. Where the material can be scooped into the measuring cup, the FS4.2 is the right choice; where the measurement is to happen at the storage point, the SG1 is.

Call us