The BLO measures the water content of material passing along a conveyor - with no sample taken and no operator. The result goes to two 4-20 mA outputs, one for moisture and one for temperature, so the controller of a boiler or a dryer works on a current figure.
The system consists of an analysing unit and a sensor matched to the mounting position. Without a sensor the device takes no measurement.
| Art. no. | Picture | Description and measuring range |
|---|---|---|
| 12122 |
![]() |
Sensor for mounting in a screw conveyor. Range 10 to 55 % water content, corresponding to 120 % wood moisture. Determination temperature 0 to +70 °C. Minimum compaction pressure of 20 N/dm² required. Also covers wood shavings, chaff and miscanthus. 5 m cable. |
| 12470 |
![]() |
Sensor with a compressing construction, for positions where the material is loosely packed. Range 10 to 55 % water content, resolution 0.5 %. Determination temperature 0 to +70 °C. Minimum compaction pressure of 20 N/dm² required. Also covers shavings, chaff and miscanthus. 5 m cable. |
| 15222 |
![]() |
Universal sensor for wood chips, pellets, sawdust and other materials. Range 2 to 60 % water content, corresponding to 150 % wood moisture - the widest of the three. Determination temperature 0 to +70 °C. 5 m cable. |
The choice depends on how firmly the material is pressed against the face of the sensor. Where a screw compacts it by itself, the 12122 is enough. Where the material passes loosely, the compressing construction 12470 is needed. The universal sensor 15222 covers the widest range and adds pellets and sawdust.
Your benefits
|
![]() |
| Parameter | Value |
|---|---|
| Article number | 12089 - analysing unit, without a sensor |
| Measuring range | depends on the sensor, see the table above |
| Calibration accuracy against the reference material | ±2.5 %, depending on the material |
| Temperature range of the analysing unit | -10 to +50 °C |
| Material temperature range for determination | depends on the sensor |
| Temperature compensation | automatic |
| Storage temperature | -20 to +60 °C |
| Protection rating | IP 54 - housing and sensor |
| Display | backlit matrix display 128 × 64 |
| Analogue outputs | 2 × 4-20 mA: water content scaled 0 to 80 %, temperature scaled -10 to +70 °C |
| Power supply | 24 VDC (18 to 29 VDC); optionally 100-240 VAC |
| Current consumption | 100 mA with the outputs unloaded |
| Dimensions of the analysing unit | 250 × 185 × 75 mm |
| Weight of the analysing unit | 1.10 kg |
| Menu languages | English, German, Italian, French, Spanish, Portuguese, Czech, Russian, Polish, international |
The sensor is not part of the set - it is chosen separately from the table above.
Checking the readingsThe manufacturer recommends comparing the readings periodically with the oven method. For a quick check there is the test block art. no. 12308, listed in the price list for the BLO and for the sensors 12122 and 12470. |
![]() |
The HGT-A is a single instrument: sensor and electronics in one housing, mounted straight into the wall of the conveyor, factory calibrated for wood chips and accurate to ±5 %. The BLO is an analysing unit with a separate sensor - it costs more and needs room for the unit itself, but it is accurate to ±2.5 %, has a display with a logger on the spot and a choice of three sensors, including the universal one that covers pellets and sawdust.