Application
The humimeter PMP (the direct successor to the P2) measures the absolute water content of paper and solid board stacked in a pile. The measurement is non-destructive and needs no sample preparation: the device is placed on top of the stack and the result appears in seconds.
The typical user is a printing house, a paper wholesaler or a packaging manufacturer - the PMP is above all for checking an incoming delivery and documenting the state of the paper before production.
When the PMP is not the right instrument
- For measuring a reel in motion the humimeter PM5 is needed.
- For corrugated board the humimeter RH5 with its sword probe is needed.
The manufacturer states both limits explicitly. The PMP covers paper and solid board - corrugated board, with its fluted structure, is measured differently.
Calibration curves selected by the density of the paper
The PMP carries 21 calibration curves and they are chosen by the density of the material, not by its trade name. The range covers densities from 300 to 1300 kg/m³ - from tissue and filter paper (300 to 450 kg/m³), through newsprint (about 600 kg/m³), to brochure papers and cartons (1050 to 1300 kg/m³).
If the material in use fits none of the curves, the manufacturer prepares one from a laboratory analysis (art. no. 11217) or loads an existing curve into the device (art. no. 12297).
How a measurement is taken
- Select the curve matching the density of the paper.
- Stack the material at least 25 mm high. On a reel, hold the meter against the side of the reel.
- Place the device flat and press with a force of about 4 kg - the sensor surface has to touch over its whole area.
- Read the result. The measurement reaches 20 mm deep, so it describes the inside of the stack rather than the top sheet alone.
- Repeat at several points to catch differences within the pallet.
Main features
- Range 1 to 15 % water content, depending on the material
- Resolution 0.1 % water content and 0.1 °C / °F for temperature
- Measuring depth 20 mm - a result from inside the stack
- 21 calibration curves selected by the density of the paper
- Non-destructive measurement in seconds, with no sample preparation
- Automatic temperature compensation
- Hold function and an automatic and manual logger for 10 000 readings with measuring point reports
- Test plate included for checking the readings yourself
- Backlit matrix display 128 × 64
- Multilingual menu
|
|
 |
Technical data
| Parameter |
Value |
| Measuring range |
1 to 15 % water content (depending on the material) |
| Resolution |
0.1 % water content; 0.1 °C / °F for temperature |
| Measuring depth |
20 mm |
| Minimum material thickness |
25 mm |
| Paper density range |
300 to 1300 kg/m³ |
| Number of calibration curves |
21 |
| Paper temperature |
0 to +50 °C / 32 to 122 °F |
| Temperature compensation |
automatic |
| Measuring time |
a few seconds, with no sample preparation |
| Memory |
hold function, automatic and manual logger for 10 000 readings with measuring point reports |
| Display |
backlit matrix display 128 × 64 |
| Storage temperature |
-20 to +60 °C |
| Protection rating |
IP 40 |
| Dimensions |
147 × 75 × 30 mm |
| Weight |
265 g (with batteries) |
| Power supply |
4 × 1.5 V AA alkaline batteries |
| Menu languages |
English, German, French, Italian, Spanish, Portuguese, Czech, Russian, Polish and an international version |
| Article number |
13770 |
Scope of delivery
- humimeter PMP moisture meter
- rubber protective cover
- wooden case
- test plate for checking the calibration
- 4 alkaline AA batteries
- operating manual
Checking the readings with the test plate
The manufacturer recommends a check every four weeks. A measurement taken on the test plate at 20 to 26 °C should give a result between 24.8 and 25.8. Anything outside that band means the instrument needs adjusting.
Extended accessories
- Art. no. 12278 - USB interface module with LogMemorizer basic software for recording and analysing measured data on a PC, with a USB cable
- Art. no. 14957 - USB interface module with its own battery supply, with LogMemorizer basic software and a USB cable
- Art. no. 11909 - annual LogMemorizer PRO licence with cloud access; requires the USB or Bluetooth interface
- Art. no. 15444 - thermal printer with rechargeable battery (USB-C version), portable serial printer for humimeter devices with a USB interface
- Art. no. 12297 - loading an existing calibration curve into the device
- Art. no. 11217 - laboratory analysis and preparation of a calibration curve for a new material
- Art. no. 10600 - factory calibration certificate, adjustment protocol supplied with material moisture meters